In an era where energy intensity reduction is no longer optional but mandated—China’s 14th Five-Year Plan targets a 13.5% reduction in energy consumption per unit of GDP by 2025—the humble heat exchange station has emerged as a critical, yet underappreciated, node in the urban supply chain of thermal energy. Far from being passive plumbing infrastructure, modern district heating exchange stations function as intelligent thermal gateways: dynamically balancing supply-side constraints, demand-side variability, building stock heterogeneity, and climate volatility. This article moves beyond technical specifications to analyze how temperature standards—codified in national documents like GB 50034-2022 (Urban Heating System Design Code) and CJJ/T 34-2022 (Urban Heating Network Design Code)—are now acting as levers for systemic efficiency, grid resilience, and decarbonization strategy across China’s 3.2 million km² of heated urban area.
The Dual-Loop Thermodynamic Architecture: Why Primary and Secondary Temperatures Are Strategically Decoupled
At its core, a heat exchange station operates two thermally isolated hydraulic loops: the primary (heat source) side and the secondary (consumer) side. This physical separation enables independent optimization—yet their interdependence dictates system-wide performance. On the primary side, temperatures are dictated by generation economics and transmission physics. According to CJJ/T 34-2022, hot water networks operate at 110°C–150°C supply and 70°C–80°C return, while steam systems at 0.6–1.3 MPa pressure deliver saturated vapor between 160°C and 200°C. Critically, the return temperature cap (<80°C for condensate) is not merely operational—it reflects a hard thermodynamic limit: exceeding it increases pump energy, accelerates pipe corrosion, and degrades boiler efficiency due to reduced flue gas dew point margin.
On the secondary side, however, temperature design is fundamentally socio-technical. It must reconcile physiological comfort (mean radiant temperature, air velocity, humidity), building envelope performance, and safety—especially against scalding in residential and healthcare settings. The national climate zoning framework embedded in GB 50736-2012 prescribes starkly divergent setpoints: 75°C–85°C supply in严寒 (Severe Cold) zones (e.g., Harbin, Changchun), dropping to just 55°C–65°C in夏热冬冷 (Hot Summer/Cold Winter) zones (e.g., Nanjing, Wuhan). This 20°C span isn’t arbitrary—it mirrors the 30–40 K outdoor design temperature delta between these regions and directly impacts the required heat transfer surface area, pump head, and pipe insulation thickness. A misaligned secondary supply temperature can inflate capital costs by up to 18% for new district heating infrastructure, per 2023 research from Tsinghua University’s Institute of Building Environment.
Sign up free to read the full article
Create a free account to unlock full access to all articles.
Sign Up FreeAlready have an account? Sign in










